316 (A4) · A4-50 · Carbon Steel
Drop-In Anchor
Drop-in anchors that sit flush in concrete with an internal thread, for hanging threaded rod from ceilings and bolting on removable fixtures.
About the Drop-In Anchor
Drop-in anchors sit flush inside a hole in solid concrete and give you a female thread, so you can hang threaded rod for pipes, ducts and cable tray from a ceiling, or bolt handrails and formwork on and take the bolt out later. They come as Drop-In PRO (European Technical Assessment Option 7 and Part 6, fire assessed from M8) in plain and lipped styles, standard drop-ins in zinc yellow or 316 stainless, a lipped M10 x 30 bucket kit, and Mungo MEA, MEAR and ESA drop-ins, from M6 to M20. Choose the range, finish and size above; the guide below covers approvals, drill sizes and setting tools.
Also called drop in anchors, flush anchors or internally threaded anchors.
Features
- Flush internally-threaded socket
- Set with a setting tool
- Removable bolt/rod fixing
- Zinc-plated and stainless
Applications
- Suspended services and hangers (ETA-assessed Drop-In PRO or Mungo MEA, to the engineer's design)
- Hand rail fastening
- Formwork support fastening
- Hanging threaded rod for pipes, ducts and cable tray from concrete ceilings (ETA-assessed Drop-In PRO or Mungo MEA, to the engineer's design)
How a drop-in anchor works
A drop-in anchor is an internally threaded steel sleeve with an expansion cone inside. You drill a hole, drop the anchor in flush with the concrete surface and drive the cone down with a setting tool and hammer. That expands the bottom of the sleeve against the hole, and friction holds it. What is left is a flush, female thread for a bolt or threaded rod, which you can remove and refit.
Hobson lists them for handrail fastening, formwork support, mechanical, electrical and pipe brackets, and hanger systems for pipes, cable trays, ducts, ceiling frames and ceiling fans. The everyday job is hanging threaded rod from a concrete ceiling for pipes, ducts and cable tray. Hobson's AS 5216 compliance note explains that an anchor used to AS 5216 must be assessed with a European Technical Assessment (ETA), and lists Drop-In PRO among its anchors with one. So overhead services and any structural or safety-critical fixing need an ETA-assessed anchor such as Drop-In PRO, with the type, size and spacing from the engineer's or services designer's specification. The standard zinc yellow and 316 drop-ins have no ETA and their data sheet values are for non-cracked concrete only, so they are not for overhead or safety-critical fixings.
Drop-In PRO, standard or Mungo drop-in?
- Drop-In PRO (Conxtruct, zinc plated, plain or lipped): European Technical Assessments ETA-19/0673 (Option 7, non-cracked concrete) and ETA-19/0703 (ETAG 001 Part 6, multiple use in non-structural applications in cracked and non-cracked concrete, with fire resistance values). Hobson labels M8 and larger as fire rated; M6 has no fire resistance values. Hobson's AS 5216 compliance note lists Drop-In PRO among its anchors with a current ETA.
- Standard drop-in (zinc yellow M6 to M20, 316 stainless M6 to M16) and the lipped M10 x 30 bucket: no ETA. Hobson's data sheets give installation values and working loads in 32 MPa non-cracked concrete only, for light to medium duty fixings. They are not for overhead services or safety-critical fixings, which need an ETA-assessed anchor.
- Mungo MEA (zinc plated) and MEAR (316): ETA Option 7 and Part 6 on most sizes, as shown in the table, with fire resistance up to F120 part of the approval according to Mungo's sheet. M12 x 50: design it to Part 6 (ETA-18/0269), which uses the 15mm drill; we give Part 6 values only for this size. MUMMEAE01741250 is the 15mm drill version. MUMMEAE01741251 is a 16mm drill version, which the Part 6 approval does not cover (its M12 drill is 15mm), so we give no approval values for it. MEAR is 316 stainless (A4-50); Mungo's sheet refers to its approval, which is not among our documents, so check it covers your conditions.
- Mungo ESA and ESA-R: drop-in anchors with no data sheet among Hobson's documents for this range, so no installation values are given here. Ask us before you specify them.
- Lipped or plain: a lipped drop-in has a lip at the top that sits on the concrete surface; a plain drop-in has none. Drop-In PRO comes both ways (M16 lipped only); the standard lipped drop-in comes in the M10 x 30 bucket.
Drop-in anchor sizes
A drop-in anchor is sized by its internal thread: an M10 drop-in takes an M10 bolt or rod, but needs a bigger hole (12mm). Length is the anchor length, which is also its embedment.
Every range we carry, by thread size. Anchor length in mm. Drill sizes from Hobson's data sheets and ETAs; for Mungo MEA and ESA codes, from the drill size in Hobson's product description. Approval per Hobson's labels, ETAs and Mungo's MEA sheet; "fire rated" is Hobson's label term for the fire resistance assessed in the Part 6 ETA. Pack is the minimum order. Tap a number to show it in the selector above.
| Range | Thread | Length | Drill | Pack | Approval |
|---|---|---|---|---|---|
| Drop-In PRO, zinc plated (plain and lipped) | |||||
| Drop-In PRO, zinc plated (plain and lipped) | M6 | 25 | 8mm | Packs of 100 | ETA Option 7 and Part 6 |
| Drop-In PRO, zinc plated (plain and lipped) | M8 | 30 | 10mm | Packs of 100 | ETA Option 7 and Part 6, fire resistance assessed |
| Drop-In PRO, zinc plated (plain and lipped) | M10 | 40 | 12mm | Packs of 50 | ETA Option 7 and Part 6, fire resistance assessed |
| Drop-In PRO, zinc plated (plain and lipped) | M12 | 50 | 15mm | Packs of 50 | ETA Option 7 and Part 6, fire resistance assessed |
| Drop-In PRO, zinc plated (lipped only) | |||||
| Drop-In PRO, zinc plated (lipped only) | M16 | 65 | 20mm | Packs of 25 | ETA Option 7 and Part 6, fire resistance assessed |
| Drop-in anchor, zinc yellow | |||||
| Drop-in anchor, zinc yellow | M6 | 25 | 8mm | Packs of 100 | None (Hobson data sheet values) |
| Drop-in anchor, zinc yellow | M8 | 30 | 10mm | Packs of 100 | None (Hobson data sheet values) |
| Drop-in anchor, zinc yellow | M10 | 40 | 12mm | Packs of 50 | None (Hobson data sheet values) |
| Drop-in anchor, zinc yellow | M12 | 50 | 15mm | Packs of 50 | None (Hobson data sheet values) |
| Drop-in anchor, zinc yellow | M16 | 65 | 20mm | Packs of 25 | None (Hobson data sheet values) |
| Drop-in anchor, zinc yellow | M20 | 80 | 25mm | Packs of 25 | None (Hobson data sheet values) |
| Lipped drop-in bucket, zinc yellow | |||||
| Lipped drop-in bucket, zinc yellow | M10 | 30 | 12mm | Bucket of 500 with setting tool and two 12mm SDS bits | None (Hobson data sheet values) |
| Drop-in anchor, 316 stainless | |||||
| Drop-in anchor, 316 stainless | M6 | 25 | 8mm | Packs of 100 | None (Hobson data sheet values) |
| Drop-in anchor, 316 stainless | M8 | 30 | 10mm | Packs of 100 | None (Hobson data sheet values) |
| Drop-in anchor, 316 stainless | M10 | 40 | 12mm | Packs of 50 | None (Hobson data sheet values) |
| Drop-in anchor, 316 stainless | M12 | 50 | 15mm | Packs of 50 | None (Hobson data sheet values) |
| Drop-in anchor, 316 stainless | M16 | 65 | 20mm | Packs of 25 | None (Hobson data sheet values) |
| Mungo MEA, zinc plated | |||||
| Mungo MEA, zinc plated | M6 | 25 | 8mm | Packs of 100 | ETA Option 7 and Part 6 |
| Mungo MEA, zinc plated | M8 | 30 | 10mm | Packs of 100 | ETA Option 7 and Part 6 |
| Mungo MEA, zinc plated | M10 | 30 | 12mm | Packs of 100 | ETA Option 7 and Part 6 |
| Mungo MEA, zinc plated | M10 | 40 | 12mm | Packs of 50 | ETA Option 7 and Part 6 |
| Mungo MEA, zinc plated | M12 | 25 | 15mm | Packs of 50 | ETA Part 6 |
| Mungo MEA, zinc plated | M12 | 50 | 15mm | Packs of 50 | ETA Part 6 (ETA-18/0269) |
| Mungo MEA, zinc plated | M12 | 50 | 16mm | Packs of 50 | None given here (the Part 6 approval uses a 15mm drill) |
| Mungo MEA, zinc plated | M16 | 65 | 20mm | Packs of 25 | ETA Option 7 and Part 6 |
| Mungo MEAR, 316 stainless (A4-50) | |||||
| Mungo MEAR, 316 stainless (A4-50) | M10 | 40 | 12mm | Packs of 50 | Values on the Mungo MEA sheet; check its approval covers your conditions |
| Mungo MEAR, 316 stainless (A4-50) | M12 | 50 | 15mm | Packs of 50 | Values on the Mungo MEA sheet; check its approval covers your conditions |
| Mungo ESA, zinc plated | |||||
| Mungo ESA, zinc plated | M6 | 30 | 8mm | Packs of 100 | No data sheet in Hobson's documents |
| Mungo ESA, zinc plated | M8 | 30 | 10mm | Packs of 100 | No data sheet in Hobson's documents |
| Mungo ESA, zinc plated | M10 | 40 | 12mm | Packs of 50 | No data sheet in Hobson's documents |
| Mungo ESA, zinc plated | M12 | 50 | 15mm | Packs of 50 | No data sheet in Hobson's documents |
| Mungo ESA, zinc plated | M16 | 65 | 20mm | Packs of 25 | No data sheet in Hobson's documents |
| Mungo ESA, zinc plated | M20 | 80 | 25mm | Packs of 25 | No data sheet in Hobson's documents |
| Mungo ESA-R, 316 stainless (A4-50) | |||||
| Mungo ESA-R, 316 stainless (A4-50) | M6 | 30 | 8mm | Packs of 100 | No data sheet in Hobson's documents |
| Mungo ESA-R, 316 stainless (A4-50) | M8 | 30 | 10mm | Packs of 100 | No data sheet in Hobson's documents |
| Mungo ESA-R, 316 stainless (A4-50) | M10 | 40 | 12mm | Packs of 50 | No data sheet in Hobson's documents |
| Mungo ESA-R, 316 stainless (A4-50) | M12 | 50 | 15mm | Packs of 50 | No data sheet in Hobson's documents |
| Mungo ESA-R, 316 stainless (A4-50) | M16 | 65 | 20mm | Packs of 25 | No data sheet in Hobson's documents |
How to install a drop-in anchor
- Drill the hole at the drill size for the anchor (an M10 drop-in takes a 12mm hole) to the hole depth for that range, using hammer drilling.
- Clean the hole: blow the dust out.
- Drop the anchor in until it sits flush with the concrete surface.
- Set it: put the setting tool for that range and size into the anchor and hammer it until the tool seats. Hobson's setting tools give a visual check that the anchor is set.
- Fit the fixture and the bolt or rod. Hobson recommends a torque wrench: do not go over the installation torque for the range, and keep the bolt's thread engagement within the figures below.
- Keep to the minimum edge distance, spacing and concrete thickness for that range. They are part of the conditions behind every published value.
Which setting tool?
Each range has its own setting tool, sized to the anchor, and the tool is what tells you the cone has been driven far enough. Use the tool made for the range and size you are setting.
Setting tools named on Hobson's data sheets, Did You Know sheets and Mungo product listings.
| Anchor range | Setting tool | Sizes |
|---|---|---|
| Drop-In PRO (plain and lipped) | Drop-In PRO setting tool (EDTMSZM) | M6 x 25 to M20 x 80 |
| Standard drop-in, zinc yellow and 316 | Drop-in setting tool (MATMSZM) | M6 to M20; M10 x 40 uses MATMSZM100185 |
| Lipped M10 x 30 (bucket) | Red grip setting tool MATR10 (in the bucket), or MATMSZM100177 | M10 x 30 |
| Mungo MEA | MEA-WZ hand tool or MEA-SDS plus tool | Matched to anchor size and length |
| Mungo MEAR (316) | MEAR-WZ hand tool | M10 x 40 and M12 x 50 (the M8 x 30 tool suits an MEAR we do not list) |
| Mungo ESA and ESA-R | ESA-WZ hand tool | M6 to M20 |
Drop-In PRO installation values (ETA-19/0673 and ETA-19/0703)
Both Drop-In PRO ETAs give the same installation table. Conditions: hammer drilling; a bolt or rod of property class 4.6, 5.6, 5.8, 6.8 or 8.8 to ISO 898-1; bolt length = fixture thickness plus the thread engagement shown; dry internal conditions. Option 7 (ETA-19/0673) covers non-cracked concrete C20/25 to C50/60. Part 6 (ETA-19/0703) covers multiple use in non-structural applications in cracked or non-cracked concrete C12/15 to C50/60, where the slip or failure of one anchor will not significantly affect the fixture. Both ETAs say the anchorage is designed by an engineer experienced in anchorages and concrete.
Drop-In PRO (EDI plain and EDL lipped), Table C1 of the ETAs. Dimensions in mm. Torque is the maximum installation torque. In ETA-19/0703, M6 has no fire resistance values; M8 to M20 do. Tap a number to show it in the selector above.
Standard drop-in installation values and working loads
For the standard zinc yellow and 316 drop-ins and the lipped M10 x 30 (no ETA), from Hobson's three drop-in data sheets. The 316 sheet (M6 to M16) and the lipped sheet give the same values as the zinc yellow sheet for the sizes they share. Do not use these values for Drop-In PRO or Mungo codes.
The working load in tension is Hobson's figure for 32 MPa non-cracked concrete at the embedment shown, with a factor of safety of 3.0 on concrete and 2.5 on steel already included. It applies only at or above the minimum concrete thickness, edge distance and spacing in the table; the sheets give no reduction for anchors nearer an edge, closer together or in groups, so those need a design by an engineer. The bolt or rod you fit must be rated for the load too. These values are for non-cracked concrete only: overhead services and structural or safety-critical fixings need an ETA-assessed anchor such as Drop-In PRO, designed by an engineer.
Hobson drop-in data sheets 210129DS (zinc yellow, 316 stainless, lipped zinc yellow). Dimensions in mm. Hole depth equals the anchor length. Torque is Hobson's guide torque. Tension working load in kN, 32 MPa non-cracked concrete. Tap a number to show it in the selector above.
| Size | Drill | Hole depth | Max thread engagement | Guide torque | Min concrete thickness | Min spacing | Min edge distance | Tension working load (kN) |
|---|---|---|---|---|---|---|---|---|
| M6 x 25 | 8 | 25 | 10 | 4Nm | 100 | 55 | 95 | 2.3 |
| M8 x 30 | 10 | 30 | 12 | 8Nm | 100 | 60 | 95 | 3.0 |
| M10 x 30 (lipped) | 12 | 30 | 12 | 15Nm | 100 | 80 | 100 | 3.0 |
| M10 x 40 | 12 | 40 | 15 | 15Nm | 120 | 100 | 135 | 4.6 |
| M12 x 50 | 15 | 50 | 20 | 35Nm | 130 | 120 | 165 | 6.5 |
| M16 x 65 | 20 | 65 | 25 | 60Nm | 160 | 150 | 200 | 9.6 |
| M20 x 80 | 25 | 80 | 30 | 120Nm | 200 | 160 | 260 | 13.2 |
Mungo MEA and MEAR spacing, edge distance and thickness
From Mungo's MEA drop-in anchor sheet and Table B1 of the two MEA ETAs, which give separate minimums for the ETAG 001 Part 6 approval (ETA-18/0269: multiple use, non-structural, cracked and non-cracked concrete) and the Option 7 approval (ETA-18/0236: non-cracked concrete). Use the pair for the approval your design relies on; n/a means that size is not covered by that approval, or (M12 x 50) that we give its Part 6 values only. Mungo's design software and the ETAs give the rest of the design data. Part 6 values for M10 x 40 and M16 x 65 are from ETA-18/0269 Table B1; Mungo's sheet omits these sizes.
M12 x 50: design it to Part 6 (ETA-18/0269), which uses the 15mm drill; we give Part 6 values only for this size. MUMMEAE01741250 is the 15mm drill version. MUMMEAE01741251 is a 16mm drill version, which the Part 6 approval does not cover (its M12 drill is 15mm), so we give no approval values for it.
Mungo MEA data sheet and ETA-18/0269 Table B1, values in mm shown as Part 6 / Option 7. Torque is the installation torque. Part 6 values for M10 x 40 and M16 x 65 are from ETA-18/0269 Table B1; Mungo's sheet omits these sizes. MEAR values are from Mungo's sheet. Tap a number to show it in the selector above.
| Anchor | Min spacing | Min edge distance | Min concrete thickness | Torque |
|---|---|---|---|---|
| MEA M6 x 25 | 120 / 120 | 110 / 90 | 100 / 100 | 4Nm |
| MEA M8 x 30 | 130 / 90 | 140 / 120 | 100 / 100 | 8Nm |
| MEA M10 x 30 | 150 / 150 | 60 / 90 | 100 / 100 | 15Nm |
| MEA M10 x 40 | 120 / 120 | 90 / 140 | 120 / 120 | 15Nm |
| MEA M12 x 25 | 200 / n/a | 100 / n/a | 100 / n/a | 35Nm |
| MEA M12 x 50 (15mm drill), Part 6 only | 130 / n/a | 140 / n/a | 140 / n/a | 35Nm |
| MEA M16 x 65 | 140 / 200 | 125 / 120 | 160 / 160 | 60Nm |
| MEAR M10 x 40 (316) | 100 / 100 | 135 / 135 | 130 / 130 | 15Nm |
| MEAR M12 x 50 (316) | 120 / 120 | 165 / 165 | 140 / 140 | 35Nm |
Which finish for where?
- Zinc plated (Drop-In PRO, Mungo MEA and ESA) and zinc yellow (standard drop-ins): low corrosion resistance on Hobson's finish comparison, for dry indoor or enclosed fixings. Both Drop-In PRO ETAs are for dry internal conditions only.
- 316 stainless (standard 316 and ESA-R): for damp, exposed and coastal fixings. MEAR is 316 stainless (A4-50); Mungo's sheet refers to its approval, which is not among our documents, so check it covers your conditions. Hobson's corrosion guide calls for stainless in the sea spray zone and within 2m of a pool. 316 is not made to sit in seawater.
- Use a bolt or rod with the same corrosion protection as the anchor.
Drop-in anchor, concrete screw or chemical anchor?
- Drop-in anchor: a flush, removable thread in solid concrete, at a shallow embedment. Set with a setting tool; load once correctly set.
- Concrete screw: a screw-in anchor that can be removed. Its base materials, edge and spacing distances are on the concrete screw page.
- Wedge anchor or through bolt: a stud anchor fixed through the fixture, where a protruding stud is fine.
- Chemical anchor with an internal thread anchor: a flush thread set in resin, with no expansion forces on the concrete, for closer edge distances. See the chemical anchor bolts page.
Drop-in anchors in Adelaide
Allmat supplies Drop-In PRO and standard drop-in anchors, setting tools, threaded rod and drill bits to electricians, plumbers, HVAC and fire services contractors, ceiling fixers and builders across Adelaide and South Australia. Add them to a quote with the rod, nuts and washers for the job, and we will price the lot.
Drop-in anchors for services and fit-out
Drop-In PRO and standard drop-in anchors, the setting tools to suit, threaded rod and SDS drill bits are available to order from Allmat for electricians, plumbers, HVAC and fire services installers, ceiling contractors, builders and trade across Adelaide and South Australia. Order through Allmat, we pick and pack it, then click and collect from the Allmat yard or have it delivered to site.
Goes with
Questions
What size hole for a drop-in anchor?
Bigger than the thread: 8mm for M6, 10mm for M8, 12mm for M10, 15mm for M12, 20mm for M16 and 25mm for M20. The Mungo M12 x 50 coded for a 16mm drill is the exception, and no approval values are given for it here. Drill to the hole depth for the range and blow the dust out.
Do I need a setting tool for drop-in anchors?
Yes. The setting tool drives the cone to the right depth and gives a visual check that the anchor is set. Each range has its own tool: Drop-In PRO tools for Drop-In PRO, MATMSZM tools for standard drop-ins, and MEA, MEAR and ESA tools for the Mungo ranges.
How much weight can a drop-in anchor hold?
It depends on the range, size, concrete and position. For the standard zinc yellow and 316 drop-ins, Hobson gives tension working loads in 32 MPa non-cracked concrete from 2.3kN (M6 x 25) to 13.2kN (M20 x 80), with factors of safety of 3.0 on concrete and 2.5 on steel included. Those figures apply only at or above the minimum concrete thickness, edge distance and spacing in the table, with a bolt or rod rated for the load. Anchors closer together, nearer an edge, overhead or structural need an engineer's design, and overhead or safety-critical fixings need an ETA-assessed anchor such as Drop-In PRO rather than a standard drop-in.
Can drop-in anchors be used in a concrete ceiling?
Hanging services from concrete ceilings is a common use, and it needs an ETA-assessed anchor: the standard drop-ins have no ETA and their values are for non-cracked concrete only. Drop-In PRO is approved under ETAG 001 Part 6 for multiple use in non-structural applications in cracked and non-cracked concrete, with fire resistance values from M8 up. The services designer or engineer specifies the anchor, size and spacing.
Can I use drop-in anchors in brick or block?
No. All the drop-in data here is for concrete. For brick or hollow block, use a fixing whose data covers that base material, such as a chemical anchor with a sleeve.
What torque for a drop-in anchor?
It depends on the range. Standard drop-ins: Hobson's guide torque is 4Nm (M6), 8Nm (M8), 15Nm (M10), 35Nm (M12), 60Nm (M16) and 120Nm (M20). Drop-In PRO maximum torques are 4, 11, 17, 38 and 60Nm for M6 to M16.
Where can I buy drop-in anchors in Adelaide?
Order through Allmat. Order ahead by phone on 1300 03 03 63 or send your list for a quote, then click and collect from 25 Kapara Road, Gillman, or have them delivered to site.
Drop-In Anchor: sizes and finishes we supply
42 lines by type and finish. Pick one above for its product code and pack sizes.
| Head / type | Finish | Sizes | Lengths | Lines |
|---|---|---|---|---|
| Mungo MEA | Zinc Plated | M6, M8, M10, M12, M16 | 25, 30, 40, 50, 50 (16mm drill), 65 | 8 |
| Standard | Zinc Yellow Passivate | M6, M8, M10, M12, M16, M20 | 25, 30, 40, 50, 65, 80 | 6 |
| Mungo ESA | Zinc Plated | M6, M8, M10, M12, M16, M20 | 30, 40, 50, 65, 80 | 6 |
| Drop-In PRO with lip | Zinc Plated | M6, M8, M10, M12, M16 | 25, 30, 40, 50, 65 | 5 |
| Standard | 316 Stainless | M6, M8, M10, M12, M16 | 25, 30, 40, 50, 65 | 5 |
| Mungo ESA-R | 316 Stainless | M6, M8, M10, M12, M16 | 30, 40, 50, 65 | 5 |
| Drop-In PRO | Zinc Plated | M6, M8, M10, M12 | 25, 30, 40, 50 | 4 |
| Mungo MEAR | 316 Stainless | M10, M12 | 40, 50 | 2 |
| Lipped, bucket kit | Zinc Yellow Passivate | M10 | 30 | 1 |
Data sheets and documents
The documents for the product you choose are listed with the selector above. Here is every Drop-In Anchor document from Hobson Engineering.
All Drop-In Anchor documents (26)
Data sheets and technical data (8)
Standards (1)
Approvals (ETA, DoP) (6)
Did You Know flyers (3)
Guides and articles (8)
Need them in bulk?
Add the sizes you need to your quote, or send us your list and we’ll price the lot and supply it with the rest of your order.
Browse all anchors & fixings