XChem Pro Chemical Anchoring FAQ and Easy Guide: Epoxy, Hybrid, Vinylester, Polyester

A 17-page Hobson easy guide and FAQ on chemical anchoring and the XChem Pro range: Epoxy E701, Hybrid H501, Vinylester V401 and Polyester P201. It answers common questions, then gives each product's uses, gel and cure times and installation.

What this covers

  • How chemical anchors work
  • Nozzles
  • ETA options
  • Seismic C1 and C2
  • Choosing a chemical
  • Product guides

For Chemical Anchors (Chemset-Style).

Key things to remember

The essentials from this document in plain words. Check the full document before you rely on a figure.

  • Chemical anchoring bonds the anchor to the concrete with adhesive; mechanical anchoring relies on a mechanical interlock.
  • Always use the supplied nozzle: it mixes the two components properly, which is needed to reach the load capacities and the gel and cure times in the ETA.
  • ETA Option 1 covers cracked and non-cracked concrete and involves the most testing; Option 7 is for non-cracked concrete only.
  • Seismic C1 is for non-structural components, tested with a 0.5mm crack width; C2 is for structural components, tested with a 0.8mm crack width.
  • Epoxy E701 is not recommended in hollow masonry because it can drain out of the sleeve, so it has no masonry ETA; Hybrid H501, Vinylester V401 and Polyester P201 do. Hybrid H501 is a blend of vinylester and urethane.
  • Core-drilled holes need a slow curing epoxy; fast curing products are unsuitable there.
  • Design life is 50 to 100 years depending on the product and its ETA.

Who it helps: Builders, engineers and staff choosing a chemical anchor for concrete or masonry.