Hobson european technical assessment
XCHEM PRO V401 Vinylester Chemical Anchor for Masonry: European Technical Assessment ETA 24/0504
Hobson's cover and the European Technical Assessment ETA 24/0504 (7 June 2024) for XCHEM PRO V401 vinylester injection mortar used in masonry. It covers M6 to M12 threaded rods in solid clay brick, hollow or perforated brick (with a perforated nylon sleeve) and autoclaved aerated concrete (AAC).
What this covers
- Cartridges and nylon sleeves
- Curing times
- Rod dimensions and materials
- Intended use and brick types
- Installation data by brick
- Hole cleaning and injection
- Characteristic resistances
Key things to remember
The essentials from this document in plain words. Check the full document before you rely on a figure.
- For static and quasi-static loads, M6 to M12, in solid masonry, hollow or perforated masonry, or AAC. The masonry mortar must be at least strength class M 2.5. The test bricks were a solid clay brick, a hollow clay brick and an AAC block.
- Hollow and perforated brick needs the perforated nylon sleeve: 12 x 80mm for M6 and M8, 16 x 85mm for M10 and M12. Fill the sleeve 100% with resin, then insert the rod with a slight twist.
- Solid brick and AAC: drill 8, 10, 12 or 14mm for M6 to M12, with embedment 80mm to 100mm and the hole 5mm deeper than the embedment. Fill the hole about 75% before inserting the rod.
- Galvanised carbon steel rods are for dry internal conditions. Stainless A2 or A4 and HCR rods suit external exposure, including industrial and marine environments, and permanently damp internal conditions.
- Temperature range -40 to +40 degrees C. Cure before loading: at 20 to 30 degrees C, 5 minutes working time, 30 minutes in dry and 60 minutes in wet base material (longer in AAC at low temperatures).
- Maximum tightening torque is very low: 1Nm in solid clay brick, 2Nm in hollow brick and 1 to 2Nm in AAC, depending on size.
- No fire resistance performance assessed. Design is by EOTA TR 054 design method A; the brick resistances are characteristic values for engineers, not working loads.
Who it helps: Engineers and builders fixing threaded rod into brick, block or AAC masonry with a chemical anchor.
Share this document
Email it to yourself
Loading…
This document is published by Hobson Engineering, who supply this range to us. We show it here in full so you can read it next to the product; the summary above is ours. Read it on this page or download the PDF. For the most current version, ask us.