Hobson performance data
H-IT Splice Wedge Anchor, Light Duty: Performance Data
Hobson's two-page data sheet for the H-IT splice wedge anchor: an all metal, pre-assembled hammer-in anchor for light duty fixings to concrete, such as hangers for ceilings, cable trays and pipes, and drywall tracks and battens.
What this covers
- Applications
- Sizes
- Installation data
- Load performance
- Installation
Key things to remember
The essentials from this document in plain words. Check the full document before you rely on a figure.
- Two sizes, both 6mm in a 6mm hole with a 15mm head: MHWMSZSM060035 (35mm long, 50mm hole depth, up to 13mm fixture) and MHWMSZSM060065 (65mm long, 80mm hole depth, up to 35mm fixture). 7mm fixture hole.
- Sets with a hammer; no special setting tool. Tamper proof once set.
- Permissible working load in tension in 32MPa concrete, with a safety factor of 2.5 applied: 2.3kN at 22mm embedment (66mm spacing, 33mm edge distance) and 3.2kN at 30mm embedment (90mm spacing, 45mm edge distance).
- Carbon steel, zinc plated (RoHS compliant).
- Used for hanger systems, suspended ceilings, mechanical services, ventilation, suspended strapping and through fixing.
Who it helps: Ceiling, services and drywall installers making light fixings to concrete.
Share this document
Email it to yourself
Loading…
Related